Fujitsu Inverter Airconditioning Unit requires repiping.

Justen requested 2 quotes from Air Conditioning Professionals in Botany

  A full check of unit found the system not cooling, gas pressure checked and found unit lost most of it's gas due to faulty pipe flare. The install was done using R22 rated pipes but the unit is a high pressure 410a gas. Old pipes need to be removed and repipe the unit using 410a rated pipes that can handle the pressure.